kfe897

About

Name

kfe897

Biography

auto maintenance spray booth Model: BTD-15-50-C Inside dimention: 6900*3900*2650 mm L*W*H Any Size Requirements Can Be Met. Cheap but equiped with BELIMO actuator A. During painting, spray booth can offer a sealed environment with cleanness, safety and excellent lighting for the painting operation of all kind of components and different products. B. During baking, drying time, temperature and humidity in spray booth can be set according to different paint materials to achieve a perfect high-quality spraying and baking for your cars. C. Spray booth makes spraying and baking operation with no limits of all kinds of whether, thus ensuring physical fitness of operators and absolute safety of equipments. Product detail: ModelBTD-15-50-C Booth Dimensions -Internal Size(L×B×H) 15000×5000×5000 mm -External Size(L×B×H) 17260×5160×5770 mm Foundation and Floor -Loading Capacity of Galvanized GratingNO – Surface Area20M²(Rear air exhaust plenum chamber ) – Metal BasementNO – Drive-in RampsNO Wall and Door – Wall PanelDouble construction with insulations EPS 60mm – Roof PanelDouble construction with insulations EPS 50mm – 3-Folded Entrance Door With Safety Glass Window4300×4800 mm (B×H) -Operator’s Door With Safety Glass Window800×2000 mm (B×H) 2PCS Lighting – Ceiling Lightings16 Units, each 4×36 W, Total 2304W – Side Lightings22 Units, each 2×36 W, Total 1584W – Brightness>1000 Lux, IP54 Grade Filtration – PrefiltersFibreglass, Paint-Stop-Filters Plate type duel filters – Ceiling FiltersEU5 Fine Filters, 6 Units – Floor FiltersFibreglass, Paint-Stop-Filters Ventilation System -Direct Drive Motor (Fresh Air)1×7.5KW,970RPM,380V,50HZ motor certification:CE -Direct Drive Motor (Exhaust Air)1×7.5KW,970RPM,380V,50HZ motor certification:CE – Fan Capacity 25000m³/h – Air Flow Speed +/- 0.28 m/s in an empty booth Heating System – Heating ExchangerStainless Steel 1Gr18Ni9Ti -Heating Exchange Capacity1×232KW(260.000Kcal/H) -Max. Drying Temperature 80 °C – Heating time 10-15 min (from 20 to 60°С) by Drying Phase -Burner ModelRIELLO RG5D diesel burner -Heating Type (optional)Diesel / Gas Burner Control Board -Control systemStandard control delta depressurization start system, EN60204-1-2006 -FunctionPainting, baking, warm painting, emergency stop switch -PLCyes -Inverter controlOptional -Import elementmaster device import element -Overpressure Manometeryes – Alarm equipmentyesbuy Industrial Spray Booth website:http://www.btd-spraybooth.com/spray-booth/industrial-spray-booths/

Website

http://www.btd-spraybooth.com/spray-booth/industrial-spray-booths